OVK Elektries | 75 | 150 | 275 | 320 | ||
Nominale wisselspanning (50/60Hz) | Uc/Un | 60V | 120V | 230V | 230V | |
Maksimum deurlopende bedryfsspanning (AC) | (LN) | Uc | 75V | 150V | 270V | 320V |
(N-PE) | Uc | 255V | ||||
Nominale ontladingsstroom (8/20μs) | (LN)/(N-PE) | In | 20 kA/25 kA | |||
Maksimum ontladingsstroom (8/20μs) | (LN)/(N-PE) | Imax | 50 kA/50 kA | |||
Impulsontladingsstroom (10/350μs) | (LN)/(N-PE) | Iimp | 12.5kA/25kA | |||
Spesifieke energie | (LN)/(N-PE) | W/R | 39 kJ/Ω / 156 kJ/Ω | |||
Laai | (LN)/(N-PE) | Q | 6.25 As/12.5As | |||
Spanningsbeskermingsvlak | (LN)/(N-PE) | Up | 0,7 kV/1,5 kV | 1,0 kV/1,5 kV | 1,5 kV/1,5 kV | 1. 6kV/1.5 kV |
(N-PE) | As ek | 100 ARMS | ||||
Reaksie tyd | (LN)/(N-PE) | tA | <25 ns/<100 ns | |||
Back-up fuse (maks.) | 315A/250A gG | |||||
Kortsluitstroomgradering (AC) | (LN) | ISCCR | 25kA/50kA | |||
TOV Weerstaan 5s | (LN) | UT | 114V | 180V | 335V | 335V |
TOV 120min | (LN) | UT | 114V | 230V | 440V | 440V |
wyse | Weerstaan | Veilige mislukking | Veilige mislukking | Veilige mislukking | ||
TOV Weerstaan 200ms | (N-PE) | UT | 1200V | |||
UL Elektries | ||||||
Maksimum deurlopende bedryfsspanning (AC) | MCOV | 75V/255V | 150V/255V | 275V/255V | 320V/255V | |
Spanningsbeskermingsgradering | VPR | 330V/1200V | 600V/1200V | 900V/1200V | 1200V/1200V | |
Nominale ontladingsstroom (8/20μs) | In | 20kA/20kA | 20kA/20kA | 20kA/20kA | 20kA/20kA | |
Kortsluitstroomgradering (AC) | SCCR | 100kA | 200kA | 150kA | 150kA |